Home / Blog / Best Generators for a Furnace
Buying guide

Best Generators for Running a Furnace During an Outage

A furnace needs clean, stable power and a safe connection. Here are the generator types that do it well and how to choose the right size.

Updated September 17, 20266 min readThe Power Bench editorial

We earn a commission when you buy through links on this page, at no cost to you. We do not accept free products for coverage, and we never invent test results, prices, or ratings.

What a furnace needs from a generator

A gas or oil furnace does not need a huge generator. It needs the right kind of power and the right connection. Three things matter most:

  1. Clean power. Furnace control boards are electronic. Many technicians recommend inverter generators or conventional generators with low total harmonic distortion (THD) to avoid nuisance problems and protect electronics.
  2. Enough capacity for the blower motor, including startup, plus whatever else you run at the same time.
  3. A safe, code-compliant connection. Furnaces are hardwired. You need a transfer switch, interlock, or dedicated furnace transfer switch installed by a licensed electrician.

For the full background, read our winter outage heating guide.

How to size for your furnace

Find the nameplate inside the furnace cabinet door. Look for the blower motor's full-load amps and the furnace's total amperage. Multiply amps by 120 volts to estimate running watts. Motors draw more briefly at startup, so leave headroom.

Then add everything else you want to power at the same time: refrigerator, freezer, sump pump, lights, internet, and any medical equipment. Aim to keep the total comfortably below the generator's rated running watts.

ScenarioWhat you are poweringGenerator class to consider
Furnace onlyBlower, inducer, controlsSmall-to-mid inverter
Furnace plus fridge and lightsEssentials in a typical homeMid-size inverter or dual-fuel
Furnace plus sump and well pumpAdds 240V well pump surgeLarger generator with 240V output
Heat pumpLarge compressor, 240VLarge 240V generator plus soft start

What makes a generator good for furnaces

Our picks by type

Mid-size dual-fuel inverter generator

$$$

Best for Most homes with a gas furnace

Clean inverter power for control boards, dual fuel for winter flexibility, and enough capacity for a furnace plus essentials. Look for a 30-amp transfer-switch outlet and CO shutoff.

Small inverter generator

$$

Best for Furnace-only or boiler backup with a dedicated furnace transfer switch

Quiet, fuel-efficient, and clean. Enough for many furnace blowers or boiler circulators on their own. Check that its running watts cover your furnace with headroom.

Open-frame dual-fuel generator with low THD

$$

Best for Larger loads on a budget

Conventional generators offer more watts per dollar. Choose one where the manufacturer lists low THD suitable for sensitive electronics, and connect through a transfer switch.

Large 240V generator

$$$

Best for Homes with well pumps or heat pumps

More capacity and 240V output for large motors. Check surge ratings and consider a soft-start kit on heat pump compressors.

Dedicated furnace transfer switch

$$

Best for Backing up only the furnace simply

A single-circuit switch installed near the furnace lets you move it from utility power to generator power without a panel-wide transfer switch. Must be installed by a licensed electrician.

Transfer switch or interlock kit

$$

Best for Powering the furnace and other circuits safely

A panel-level solution that lets you select multiple circuits. Pair it with an outdoor inlet box. Installation by a licensed electrician is required in most jurisdictions.

Connecting to the furnace

Most furnaces are hardwired to a circuit with a service switch nearby. To run the furnace on generator power, one of these must be installed:

Safety

Never backfeed a home through a wall outlet. It can energize utility lines and injure or kill line workers. Use a transfer switch or interlock installed by a licensed electrician, with permits where required.

Troubleshooting furnace problems on generator power

Furnace starts, then locks out. A common cause is flame sensing trouble related to the generator's neutral-ground configuration, especially with some floating-neutral generators. A properly installed transfer switch or interlock usually resolves it. Have a technician check the connection.

Blower hums but will not start. The generator may not have enough surge capacity, or it is overloaded. Turn off other loads and try again.

Control board errors. Power quality may be the issue. Inverter power usually resolves it.

Fuel planning for winter

Furnaces cycle on and off, so generator load varies. In very cold weather, the furnace may run most of the time. Plan for several days of fuel. See how long a generator can run for refueling guidance.

Safety

Run generators outdoors only, well away from the house, with exhaust pointed away from windows and doors. Install battery-powered CO alarms inside. Never run a generator in a garage.

Inverter vs conventional: the trade-off

Inverter generators produce clean, stable power by converting the engine's raw output to DC and then back to AC electronically. They are quieter and more fuel-efficient at light loads because many can throttle the engine down when demand is low, which matters when a furnace cycles on and off all night. The trade-off is cost: inverters deliver fewer watts per dollar.

Conventional (open-frame) generators run the engine at a fixed speed to produce AC directly. They are louder and less fuel-efficient at partial loads, but they deliver more total watts for the money. Some manufacturers specify low THD on their conventional models, which makes them reasonable for furnaces.

For a house where the furnace is the priority and the rest of the load is modest, a mid-size inverter is the most comfortable choice. For a house that also needs a well pump or large 240V loads, a larger conventional generator with low rated THD can be the practical answer.

Questions to ask your electrician

  1. Is my furnace on its own dedicated circuit?
  2. Would an interlock kit or a manual transfer switch suit my panel better?
  3. What inlet and cord rating matches my generator's largest outlet?
  4. Will the connection preserve the home's neutral-ground bond so the furnace's flame sensor works properly?
  5. Do I need a permit and inspection where I live?

Maintenance for winter readiness

Run the generator monthly under some load. Change oil on the manufacturer's schedule. Use fuel stabilizer in stored gasoline, or run the carburetor dry before storage if the manufacturer recommends it. Keep a spare spark plug, oil, and the tools to change them. A generator that will not start during a snowstorm is worse than no generator at all, because you planned around it.

What about standby generators?

Permanently installed standby generators with automatic transfer switches start themselves when the power fails and run on natural gas or propane. They are the most convenient way to keep a furnace running, but they cost considerably more and require professional installation and permits. Portable generators with a transfer switch are the budget-friendly middle ground for most homes.

A note on extension cords

You may see advice online to cut the furnace's power cord or wire a plug onto a hardwired furnace so it can be plugged into a generator cord. Codes on this vary by jurisdiction, and improvised wiring creates shock and fire risks. The safe, simple path is a transfer switch, interlock, or dedicated furnace transfer switch installed by a licensed electrician.

Frequently asked questions

What kind of generator is best for a furnace?

An inverter generator or a conventional generator with low rated harmonic distortion, sized for the furnace plus essentials, and connected through a transfer switch or interlock.

How many watts does a furnace blower use?

It varies widely by motor type and size. Check the nameplate amperage and multiply by 120 volts for an estimate, then allow for startup.

Can I run my furnace on a 3000-watt generator?

Often yes for the furnace alone, but check your blower's nameplate. You will not have much capacity left for other loads.

Why does my furnace lock out on generator power?

Often it is a flame sensing issue related to neutral-ground bonding. A properly installed transfer switch or interlock usually resolves it. Consult a technician.

Do I need an electrician to connect a generator to my furnace?

Yes. Furnaces are hardwired, and a transfer switch, interlock, or furnace transfer switch should be installed by a licensed electrician.